Technical Specification:
| Display | 7 inch TFT color screen, 800*480 resolution |
| Operation mode | Button, Rotary, Touch Screen |
| Power supply | Lithium Ion Battery |
| Battery capacity | 5.0Ah |
| Power voltage | 12V |
| Power quantity | 1 |
| Working time | ≥8 hours |
| Adapter input | DC100~240V 50Hz/60Hz |
| Adapter output | AC 12V |
| Adapter power | 36W |
| Data storage | SD card(16G) |
| Alarm | 1 |
| Working Temperature | -10ºC~45ºC |
| Storage Temperature | -20ºC~60ºC |
| IP Grade | IP65 |
| Dimension | 245*155*55mm |
| Weight | 1.18kg (included battery) |
| Conventional UT Model | |
| Probe Connector type | LEMO 00 |
| Channel Type | Single channel |
| Channel Num | 500 group(able to be scaled) |
| Pulse Type | Negative sharp wave |
| Transmit Voltage | 50~350V, step in 50V |
| Damping | 560Ω |
| Gain | 0~110dB, step: 0.5/2/6/12dB |
| Gain Fine Adjustment | -4~+4 |
| Surface compensation | All Gain Range |
| Working Frequency | 0.5~20MHz; |
| Probe Type | Single, Dual, Through, Immersion type |
| Filter | Three optional: 1~4MHz/0.5~10MHz/2~20MHz |
| Detection Mode | Negative / Positive / Two-way / RF |
| Reject | 0~80%, step 1% |
| Testing Range | 0~15000mm, Minimum display range: 15mm (in steel) |
| Material Velocity | 100~20000m/s |
| Pulse displacement | -10~1000mm |
| P DELAY | 0~200us |
| X-VAL | 0~100mm |
| Guide | Weld, Sheet, Forging inspection |
| Testing Point | Peak/X-val/J val |
| Measurement | Gate: Amplitude, Amplitude dB value, Range, Horizontal distance, Vertical distance, The difference value between A and B Gate Cursor: 2 cross cursors, can test the horizontal and vertical distance, and the distance between cursors(under B scan function) |
| Gate | Gate start: all range |
| Gate width: all range | |
| Gate level: 10~90%, step: 1% | |
| Curve | DAC, maximum six curves, meet to NB/T 47013,GB/T 11345,GB/T 29712, and other standards |
| TCG, maximum six curves | |
| AVG | |
| Other functions | Full screen, cursor switch(range/Height/Horizon), single/continuous auto gain(10~100%, step 10%), echo compare,echo full, peak envelope,peak memory,fast scan,outside mode,screenshot |
| Peak freeze/Crack depth/Gate expansion//curved surface modification/ B scan/Flat weld simulation//video | |
| Alarm | Sound and light alarm |
| Sensitivity Leavings | ≥65dB(200mm-Φ2FH,2.5PΦ20) |
| Horizontal linearity error | ≤0.3% |
| Vertical linearity error | ≤3% |
| Amplitude linearity error | ≤±2% |
| Attenuator accuracy | 20dB ±1 dB |
| Dynamic range | ≥32dB |
| Distant resolution | ≥26dB |
| Noise Level | <40×10-9 V/ |
| Name | QTY | |
| 1 | Main unit | 1 |
| 2 | Straight probe 10mm 2.5MHz | 1 |
| 3 | Angle probe 13x13 K2 2.5MHz | 1 |
| 4 | probe connecting cable | 2 |
| 5 | Power adaptor | 1 |
| 6 | Warranty card | 1 |
| 7 | Product Certificate | 1 |
| 8 | Instruction manual | 1 |
| 9 | Software | 1 |
| 10 | Instrument case | 1 |
| Angle Beam Probe | 6×6,8×9,10×10, 13×13,14×16,18×18, 20×20,20×22, 30×30 | Straight Beam Probe (softfilm) | Φ6,Φ8,Φ10,Φ12, Φ14,Φ16,Φ20,Φ24, Φ25,Φ30 |
| Dual Element Beam Probe (Softfilm) | Φ8,Φ10,Φ12, Φ14,Φ20, Φ25,Φ30, | Immersion Probe | Φ10,Φ14, Φ20,Φ25 |
| Water filled Probe | Φ20,Φ25 | Small Angle Probe | Φ14,Φ20, Φ25,18×18 |
| Dual Element Straight Beam Probe (Softfilm) | 8×9,10×12 | Surface Wave Probe | 10X12 |
| Creeping Wave Probe | 8×12,6×6 | Small-diameter Probe | 5×5,5×7 |
| Plate Wave Probe | 20×30 | Variable Angle Probe | 10×10,10×12 |