• Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
  • Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System

Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System

Warranty: 1 Year
Wavelength Range: 165~589nm
Spark Frequency: 100-1000Hz
Measurable Elements: Fe, Al, Cu, Ni, Ti, Co, Zn, Sn, Mg, Pb, etc
Discharge Current: 1-400A
Pixel Resolution: 30pm
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ES-9L
Detector
High Resolution CCD Multi Detectors
Focal Length
400mm
Electrode
Tungsten Electrode Technology
Transport Package
Plywood Box
Specification
800*700*470mm
Trademark
EBP
Origin
Zhejiang, China
HS Code
9024109000
Production Capacity
90 Sets Per Month

Product Description

Benchtop Optical Emission Spectrometer (ARC / Spark - OES)

ES-9L is Full Range of Solutions for the Entire Metals Industry. It use full-digital technology to replace bulky photomultiplier tube (PMT) simulation technology and keep pace with international spectrometer technology. The adoption of vacuum optical chamber design, full-digital excitation light source, advanced CCD detectors, and high-speed data readout system equips the device with high properties, ultra-low limit of detection (LOD), long-term stability and repeatability. The analytical precision can meet the requirements of laboratory standard, the analytical date is stable and reliable. Widely used in Metallurgy, casting, machinery processing and other industries incoming and outgoing product quality control.

Specification:
Item Index





Optical System
Focal Length 400mm
Wavelength range 165~589nm (Extendable)
Detector High resolution CCD Multi detectors
Degree of vacuum Auto control within 6-20 pa
Pixel resolution 30pm
Grating line 2400m1/mm
First order spectral line dispersion rare 1.2nm/mm
Average resolution ratio 10pm/pixel
Full spectrum
Light room temperature is controlled automatically




Spark Source
Type Digital arc and spark source
Spark frequency 100-1000HZ
Discharge current 1-400A
Ignition voltage >15000V

Excitation light
Optimization of discharge parameters design
High energy precombustion technology HEPS

Processor
High-speed data synchronization acquisition and processing


Spark Stand
Electrode Tungsten electrode technology
Make up Thermal deformation self-compensation design
Argon flushed with minimal consumption of Argon
Spray discharge electrode technology
Adjustable electrode technology




Others
Measurable elements Fe,Al,Cu,Ni,Ti,Co,Zn,Sn,Mg,Pb  etc
Dimension 800mm(L)*700mm*470mm(H)
weight About 100kg
Storage temperature 0ºC-45ºC
Operating temperature 10ºC-35ºC, 23±2ºC is recommended
Power AC220V/50Hz(Customized)
Power consumption Excitation:700W/Stand by:100W
Argon quality 99.999%, Argon pressure>4Mpa
Argon consumption 5L/min during spark mode
Interface Ethernet data transmission based on DM9000A

Main Features:
1.Optimized vacuum optics system
(1) Integrated optics room and Paschen Runge construction design, making all the spectrum lines focused on the gratings.
(2) Direct-jet type optics technology and MgF2 material lens to make sure ultraviolet wave′s best energy of elements, such as C,S, P and N.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
2. Automatic Light-Path Correction
(1) With automatic light path correction, optical system automatically scans the spectral lines to ensure the correctness of received lines and avoid tedious scanning of wave peaks.
(2) The instrument automatically identifies specific spectral lines and compares them with original stored lines to determine the location of the drift and find the present pixel position for analysis among the lines.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
3. Single-Board Lens Design
(1) The adopted specialized entrance window separating from vacuum in the vacuum optical system can be operated under the system working status. The adopted single-board lens structure in the optical lens is convenient for routine cleaning and maintenance.
(2) It is not required to maintain the device in the daily operation, and there is no consumable and renewal part.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
4. Optical Chamber Integration
(1) Specialized optical chamber structural design makes the volume of the chamber smaller, with less than half air exhaust speed of ordinary spectrometers.
(2) Integrated design and high-precision processing in the vacuum chamber improves the duration of vacuum.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
5. Vacuum Anti-Oil-Returning Technology
(1) Multi-level separating vacuum anti-oil-returning technology absorbs vacuum compaction and baffle valves to ensure the complete separation of vacuum optical chamber from vacuum pump during non-operation time.
(2) The intermediate addition of vacuum oil filtering device ensures the oil inside the vacuum pump not to enter the vacuum chamber, and ensures CCD detectors and optical components to work under reliable situation.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
6. Open-Access Inspire Stand
(1) Flexible sample clamp design of Open-Access Excitation Stand satisfies user on-site analysis of samples with different sizes and shapes
(2) The small sample clamps in cooperative use can make the analytic precision of wire rods achieve 1.5 mm at the minimum.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
7. Injection Electrode Technology
(1) The instrument adopts the most internationally-advanced injection electrode technology with tungsten used. Under the status of excitation, the electrode forms argon gas injection flow surrounded. Thus, there is no opportunity for the surrounding excitation points to contact external air so as to improve precision of excitation.
(2) The attached specialized argon gas channel design significantly reduces the usage amount of argon gas and use cost for customers.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
8. Integrated Gas Channel Block
(1) The excitation stand is made of alloys with good heat dissipation to achieve solidity, durability and cleaning convenience.
(2) The gas supply system adopts integrated gas channel block and electrode self-flushing function to create good environment for excitation.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
9. Full Digital Inspire Light Source
(1) The system uses the most internationally-advanced plasma inspire light source, and generates ultra-stable energy release to excite samples in the environment filled with argon gas.
(2) Full Digital Inspire Light Source ensures ultra-high resolution and high-stability output rate of plasma in the excitation samples.
(3) Full Digital Inspire Light Source can satisfy inspire requirements for different type of materials.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
10. High-Speed Data Acquisition
(1) The instrument adopts high-performance CCD devices, UV coating technology and high-performance FPGA, DSP and ARM processors.
(2) The system has ultra-high functions of data acquisition and analysis, and can realize automatic real-time monitoring and control of the block operation status of optical chamber temperature, vacuum degree, argon gas pressure, light source and excitation chamber.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
11. Ethernet Data Transfer
(1)  Ethernet cards and TCP / IP protocol are connected between computers and spectrometers to avoid electromagnetic interference, fiber aging defects. Meanwhile, the computers and printers are completely placed in external position for the benefit of promotion and substitution.
(2) Complete network systems.
(3) The system can remotely monitor the status of devices, operate the system through multiple channels, as well as control and monitor all the instrumental parameters.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
12. Pre-Set Working Curves
(1) The analysis programs in terms of elements and materials exist slight difference. The parameters of excitation and measurement have been adjusted before delivery. Customers can automatically choose optimal measurement conditions according to analysis programs.
(2) Over a long period of time, the factory has been accumulating a large amount of experience and comprehensive international standard sample base. The factory pre-sets the working curves before delivery to benefit customers to put the device into use immediately after receiving.
(3) The analysis range is attached to the technical specification (the system can plot or prolong working curves for free according to samples provided by customers).
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
13. Fast Analysis Speed
(1) The fast analysis speed saves time for customers by finishing the element component analysis through all channels within 20 seconds.
(2) According to the specific type of materials to be analyzed, it is available to make the instruments achieve the best analysis results within the minimum duration by setting pre-burning time and measurement time.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
14. Multiple Matrices Analysis
(1) The light-path design absorbs the structure of Rowland circle and vertically interleaved CCD arrays to ensure all the spectral lines to be received. No hardware is required to realize analysis of multiple matrices.
(2) It is convenient to add up matrices, material types and analysis elements according to the requirements of production.
(3) Compared with photomultiplier tubes (PMTs), spectrometers can significantly decrease use cost and increase the range of usage.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
15. Software with Multiple National Languages
  1. The instrumental operating software is completely compatible with Windows system, and can be equipped with specific language versions according to user requirements.
  2. The software is easy to use. Even those staff without any knowledge and experience about spectrometers can easily use the software after a short simple training.
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System

Analytical Program
  Fe-001 Fe-002
No Elements Low Alloy Steel Cast Iron
1 C 0.006-1.3 1.8-4.5
2 Si 0.01-2.9 0.2-4.2
3 Mn 0.03-14 0.06-4.7
4 P 0.002-0.12 0.02-0.8
5 S 0.002-0.46 0.003-0.2
6 Cr 0.01-12.5 0.03-2.8
7 Ni 0.004-4.4 0.05-5.1
8 Mo 0.004-1.76 0.01-2.1
9 Al 0.003-0.5 0.002-0.25
10 Cu 0.002-0.7 0.06-2.0
11 Co 0.001-0.5 0.008-0.03
12 Ti 0.002-0.5 0.007-0.7
13 Nb 0.002-0.53 0.002-0.7
14 V 0.003-0.9 0.01-0.7
15 W 0.03-2.1 0.007-1.0
16 Mg   0.001-0.14
17 B 0.006-0.02 0.002-0.3
18 Sn 0.001-0.09 0.003-0.3
19 Zn 0.002-0.04 0.005-0.03
20 As 0.001-0.1 0.008-0.09
21 Zr 0.004-0.45  
22 La   0.002-0.12
23 Ce   0.04-0.1
24 Sb 0.002-0.02 0.004-0.2
25 Fe Reference Reference
Note:
The instrument is calibrated with limited standard samples which EBP Instruments have for general purpose. For special alloy and special elements, the instrument must be calibrated by customer themselves. Or if customer is willing to provide sample collaboration for program development, the customer must provide accurate sample element content tables and ensure sample uniformity, but such curves are not used as acceptance indicators of the instrument.
Supply list   
No. Item Specifications QTY Unit Remarks
1 Optical Emission Spectrometer TY-9000 1 Set Include in quotation.
2 Business computer   1 Set
3 Printer   1 Set
4 Tungsten electrode   1 Pc
5 Electrode pressure spring   1 Pc
6 The electrode fixed screw   2 Pcs
7 Electrode brush Φ6 2 Pcs
8 Lens holder sealing ring Φ16×2.65 2 Pcs
9 Spark stand sealing ring Φ72×2.65 1 Pc
10 Exhaust gas filter core   1 Pc
11 Degreasing cotton   15 G
12 Power socket   1 Pc
13 M2 Internal hexagonal wrench   1 Set
14 M4 Internal hexagonal wrench   1 Set
15 Long handle phillips screwdriver   1 Pc
16 13-15 fixed wrench   1 Pc
17 Spark stand screw M6 4 Pcs
18 Fuse 10A 2 Pcs
19 Argon gas pressure reducing valve   1 Pc
20 Argon gas pipeline   2 M
21 Exhaust pipe   1 Pc
22 Gas bottle   2 Pcs
23 Print paper   1 Pc
24 Spectrometer manual   1 Set
Notes: The Buyer knows and agrees that the Seller may adjust the supply when the production of the above-mentioned instruments, spare parts and other suppliers change due to technological progress, product upgrading, market changes, etc.


Optional items:
Optional item Qty Note
High purity argon gas (pure >= 99.999%) 1 bottle Should prepare by customer. If can't get should use argon purifier to get 99.999% argon gas.
Small air conditioning 1 set Essential, customer should prepare by themselves.
High precision magnetic saturation voltage stabilizer (1KVA) 1 set Need for voltage instability, if the customer uses intermediate frequency furnace, then need 3KVA Voltage Stabilizer
Argon purifier 1 set When argon gas is not as pure as 99.999%.
Samples grinder (ferrous metals) or Mini lathe (non-ferrous metals) 1 set Essential
Type samples pieces Essential for foundry



Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System
Full-Digital Benchtop Optical Emission Spectrometer (ARC / Spark - OES) with Data Readout System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now